{"product_id":"r422d-mo29-5-lbs-refrigerant-professional-check-charge-it-kit-1","title":"R422d, (MO29), 5 Lbs., Refrigerant, Professional Check \u0026 Charge-It Kit","description":"\u003cp\u003e\u003cstrong\u003eR422d, (MO29), 5 Lbs., Refrigerant, Professional Check \u0026amp; Charge-It Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cem\u003ePlease use the R22 scale for R422d (MO29) as the pressure\/temperature relationship is similar!\u003c\/em\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e(1) R422d, 5 Lb., tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFactory fresh and sealed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe tank has the standard 1\/4\" male flare hose connection.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe tank also has a on\/off valve.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003e*The tank is factory sealed in the new EPA \u0026amp; AHRI required color for ALL new tanks made as of 2020 which is Gray.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003cstrong\u003eThe best replacement for R22 Refrigerant in commercial refrigeration applications is R422d.\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eUsed in Europe for over a decade, R422d refrigerant is the only PROVEN R-22 replacement and is being manufactured and is available in the United States. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant is a true drop-in replacement, and no system changes are required. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eDon`t worry about oil changes and rest assured R422d refrigerant is good for cap tubes and TXV. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eIt operates at lower discharge pressure and temperature than R22, which is great for the compressor.\u003cbr\u003e\u003cbr\u003eAdvantages\u003cbr\u003e\u003cbr\u003eR422d refrigerant is the approved R22 replacement drop- in refrigerant by Carrier Commercial.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant operates in R22 systems without requiring an oil change to expensive synthetic oil.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant has the benefit of lower energy consumption.\u003cbr\u003eR422d refrigerant operates at near capacity of R22.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant operates at lower discharge pressure \u0026amp; temperatures thereby reducing compressor workload.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant can be mixed with R22 without any system performance problems (if a service tech, inadvertently mixes the two refrigerants).\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant has been operating in all types of systems with all types of compressors worldwide for the past 10 years. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eNo other R22 alternative refrigerant can make this claim.\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant is produced in Texas, the UK and China.\u003cbr\u003e\u003cbr\u003eType and Description\u003cbr\u003e\u003cbr\u003eR422d refrigerant is a non flammable blend of HFC 125, HFC 134a, n-butane, isobutane and isopentane which is zero ODP. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eIt is compatible with both traditional mineral and synthetic lubricants so that a retrofit is not required. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eThe hydrocarbons in RS-44 improve the oil return to the compressor to extend the life of the compressor.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant is a direct replacement for R22, providing an easy and at the same time a long term solution. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eBecause there is no need to use expensive and hygroscopic synthetic lubricants (POE), the risk of moisture ingress into a refrigeration system is completely avoided. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eR422d refrigerant has significantly lower discharge temperatures and pressures than R22 which removes the problem of oil decomposition and improves the coefficient of performance and saves wear on the compressor.\u003cbr\u003eApplications\u003cbr\u003e\u003cbr\u003eR422d refrigerant is suitable for use as a replacement for R- 22 in existing residential, commercial and industrial air conditioning and refrigeration systems, and appliances.\u003cbr\u003e\u003cbr\u003eService Work\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eBecause it is a blend, it is recommended that R422d refrigerant be charged into systems as a liquid as opposed to the gaseous phase. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eSince there is no need to change the existing lubricant, RS-44 is straightforward to use, as the following procedure outlines.\u003cbr\u003e\u003cbr\u003eLubricants\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003e\u003cbr\u003eR422d refrigerant is compatible with both mineral and alkybenzene oils found in R22 systems, and also with the polyolester lubricants. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eTherefore, there is no need to change the lubricant although compressor manufacturers' recommendations regarding lubricity should be followed.\u003cbr\u003e\u003cbr\u003eMaterials Compatibility\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003e\u003cbr\u003eR422d refrigerant is compatible with all materials commonly used in refrigeration systems previously charged with R22.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003e In general, materials which are compatible with R22 can be used with RS-44. \u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003elt is recommended to check equipment manufacturer's retrofit literature and obtain recommendations from equipment manufacturers with regard to materials' compatibility.\u003cbr\u003e\u003cbr\u003eEnvironmental Data\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\u003cstrong\u003eNone of the components of R422d refrigerant contains chlorine so that it has no ability to deplete the ozone layer.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv data-cl-template-tag=\"description\" data-exclude-css-removal=\"true\"\u003e\n\u003cp\u003e\u003cstrong\u003eR422d refrigerant does have a direct global warming potential (GWP), but this is counterbalanced by its lower Total Equivalent Warming Impact (TEWI). \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests have shown that R422d refrigerant has a higher Coefficient of Performance (COP) than R22 in a range of applications including commercial refrigeration systems and heat pumps, both in the heating and cooling mode.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Gregoriou Brothers","offers":[{"title":"Default Title","offer_id":42281620439122,"sku":"403800643796_B444_1EB6","price":381.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0005\/5643\/3461\/files\/Untitled-1_da7da343-0eaa-4b6b-8490-fe60fb79a975.jpg?v=1770559171","url":"https:\/\/frosty-freezeacproducts.com\/products\/r422d-mo29-5-lbs-refrigerant-professional-check-charge-it-kit-1","provider":"Frosty Freeze A\/C Products Company","version":"1.0","type":"link"}