R404a, 404a, R-404, Recharge Kit, 28 oz, w/Check & Charge-It Gauge & Hose KIT C
Regular price
$239.95
Sale
& Hose KIT C
Refrigerant R-404a, also known as HP-62 and FX-70.
One 28 oz. Disposable can.
Alternate for R502.
This kit is for Recharging a Refrigerant R-404a system.
Refrigerant R404a is used on coolers and freezers.
This recharge kit includes;
(1) 28 oz. Can of R-404a with a CGA600 Top Connection.
(1) CGA600 R404 Gauge with a on/off valve and a 1/4" male flare fitting hose connection.
(1) Reusable , Quick Connect (screw-on), Top Mount Can Taper with On/Off Valve.
(1) SPECIAL, R404a, "CHECK & CHARGE-IT" Gauge.
Gauge also shows the correct temperature/pressure relationship. (Used for adjusting superheat.)
(1) 36" Charging Hose with a valve core depressor on one end.
(1) Sid Harvey Pocket screwdriver with valve core tool built into the handle and a regular flat blade.
****CANADA CUSTOMERS*****
We will include a copy of the eBay invoice with this item as UPS in Canada requires this.
You will have to pay your custom charges and all other charges that apply in Canada.
We have no way of knowing what those charges are or will be.
You can contact your local UPS store with questions on your costs for custom charges.
Refrigerant R-404A DOES NOT REQUIRE EPA CERTIFICATION TO PURCHASE HOWEVER ALL OUR REFRIGERANT KITS ARE FOR PROFESSIONAL USE ONLY BY QULIFIED HVAC TECHNICIANS ONLY.
****FOR USE BY QUALIFIED Refrigeration and Air Conditioning TECHNICIANS.
USE ONLY IN AIR CONDITIONING SYSTEMS DESIGNED FOR R404A.
DO NOT MIX WITH ANY OTHER REFRIGERANT.
Refrigerant Can Notes
**WARNING**
*ALWAYS WEAR EYE PROTECTION WHEN WORKING WITH REFRIGERANTS.
*ALWAYS WEAR GLOVES WHEN WORKING WITH REFRIGERANTS.
*CONTENT UNDER PRESSURE.
*VAPOR HARMFUL SKIN AND EYE IRRITANT.
DO NOT CONNECT THIS CAN TO THE HIGH PRESSURE SIDE OF THE SYSTEM, THIS MAY CAUSE THE CAN OR CONTAINER TO
BURST AND RESULT IN SERIOUS INJURY.
ALWAYS REPAIR LEAKS BEFORE ADDING REFRIGERANT.
USE ONLY IN SYSTEMS DESIGNED FOR REFRIGERANT R404a.
DO NOT MIX WITH ANY OTHER REFRIGERANT.
FOR LOW PRESSURE SIDE OF THE SYSTEM ONLY!!!!
DO NOT EXPOSE THIS CAN TO HEAT OR STORE IN TEMPERATURES ABOVE 120 F.
HIGH TEMPERATURES MAY CAUSE THE CAN TO BURST.
DO NOT PUNCTURE OR INCINERATE THIS CAN.
DO NOT STORE IN PARKED VEHICLES WHERE THE INSIDE TEMPERATURE MAY EXCEED 120 F.
Do not refill can.
KEEP OUT OF REACH OF CHILDREN.
HFC refrigerants such as R-404A and R-410A,are not currently covered under the EPA Refrigerant sales restriction.
epa
You must be certified by the (EPA), Section 608 or Section 609 to purchase this item.
You must show proof of certification before paying and before the item is shipped.
*If you are purchasing this item for resale only to EPA Certified Technicians then please indicate so in a message and please keep accurate records of same.
Thank you.
SHIPPING INFORMATION: We are a U.P.S. Certified Hazardous Material Shipper for both the United States and Canada.
The package will be properly labeled as a "Hazardous Materials Package" with all the required United States Department of Transportation identification labels as required in DOT-CFR Title 49 shipping regulations including "ORMD" Limited Quantities Exemption shipments.
& Hose KIT C
Refrigerant R-404a, also known as HP-62 and FX-70.
One 28 oz. Disposable can.
Alternate for R502.
This kit is for Recharging a Refrigerant R-404a system.
Refrigerant R404a is used on coolers and freezers.
This recharge kit includes;
(1) 28 oz. Can of R-404a with a CGA600 Top Connection.
(1) CGA600 R404 Gauge with a on/off valve and a 1/4" male flare fitting hose connection.
(1) Reusable , Quick Connect (screw-on), Top Mount Can Taper with On/Off Valve.
(1) SPECIAL, R404a, "CHECK & CHARGE-IT" Gauge.
Gauge also shows the correct temperature/pressure relationship. (Used for adjusting superheat.)
(1) 36" Charging Hose with a valve core depressor on one end.
(1) Sid Harvey Pocket screwdriver with valve core tool built into the handle and a regular flat blade.
****CANADA CUSTOMERS*****
We will include a copy of the eBay invoice with this item as UPS in Canada requires this.
You will have to pay your custom charges and all other charges that apply in Canada.
We have no way of knowing what those charges are or will be.
You can contact your local UPS store with questions on your costs for custom charges.
Refrigerant R-404A DOES NOT REQUIRE EPA CERTIFICATION TO PURCHASE HOWEVER ALL OUR REFRIGERANT KITS ARE FOR PROFESSIONAL USE ONLY BY QULIFIED HVAC TECHNICIANS ONLY.
****FOR USE BY QUALIFIED Refrigeration and Air Conditioning TECHNICIANS.
USE ONLY IN AIR CONDITIONING SYSTEMS DESIGNED FOR R404A.
DO NOT MIX WITH ANY OTHER REFRIGERANT.
Refrigerant Can Notes
**WARNING**
*ALWAYS WEAR EYE PROTECTION WHEN WORKING WITH REFRIGERANTS.
*ALWAYS WEAR GLOVES WHEN WORKING WITH REFRIGERANTS.
*CONTENT UNDER PRESSURE.
*VAPOR HARMFUL SKIN AND EYE IRRITANT.
DO NOT CONNECT THIS CAN TO THE HIGH PRESSURE SIDE OF THE SYSTEM, THIS MAY CAUSE THE CAN OR CONTAINER TO
BURST AND RESULT IN SERIOUS INJURY.
ALWAYS REPAIR LEAKS BEFORE ADDING REFRIGERANT.
USE ONLY IN SYSTEMS DESIGNED FOR REFRIGERANT R404a.
DO NOT MIX WITH ANY OTHER REFRIGERANT.
FOR LOW PRESSURE SIDE OF THE SYSTEM ONLY!!!!
DO NOT EXPOSE THIS CAN TO HEAT OR STORE IN TEMPERATURES ABOVE 120 F.
HIGH TEMPERATURES MAY CAUSE THE CAN TO BURST.
DO NOT PUNCTURE OR INCINERATE THIS CAN.
DO NOT STORE IN PARKED VEHICLES WHERE THE INSIDE TEMPERATURE MAY EXCEED 120 F.
Do not refill can.
KEEP OUT OF REACH OF CHILDREN.
HFC refrigerants such as R-404A and R-410A,are not currently covered under the EPA Refrigerant sales restriction.
epa
You must be certified by the (EPA), Section 608 or Section 609 to purchase this item.
You must show proof of certification before paying and before the item is shipped.
*If you are purchasing this item for resale only to EPA Certified Technicians then please indicate so in a message and please keep accurate records of same.
Thank you.
SHIPPING INFORMATION: We are a U.P.S. Certified Hazardous Material Shipper for both the United States and Canada.
The package will be properly labeled as a "Hazardous Materials Package" with all the required United States Department of Transportation identification labels as required in DOT-CFR Title 49 shipping regulations including "ORMD" Limited Quantities Exemption shipments.
Refrigerant R-404a, also known as HP-62 and FX-70.
One 28 oz. Disposable can.
Alternate for R502.
This kit is for Recharging a Refrigerant R-404a system.
Refrigerant R404a is used on coolers and freezers.
This recharge kit includes;
(1) 28 oz. Can of R-404a with a CGA600 Top Connection.
(1) CGA600 R404 Gauge with a on/off valve and a 1/4" male flare fitting hose connection.
(1) Reusable , Quick Connect (screw-on), Top Mount Can Taper with On/Off Valve.
(1) SPECIAL, R404a, "CHECK & CHARGE-IT" Gauge.
Gauge also shows the correct temperature/pressure relationship. (Used for adjusting superheat.)
(1) 36" Charging Hose with a valve core depressor on one end.
(1) Sid Harvey Pocket screwdriver with valve core tool built into the handle and a regular flat blade.
****CANADA CUSTOMERS*****
We will include a copy of the eBay invoice with this item as UPS in Canada requires this.
You will have to pay your custom charges and all other charges that apply in Canada.
We have no way of knowing what those charges are or will be.
You can contact your local UPS store with questions on your costs for custom charges.
Refrigerant R-404A DOES NOT REQUIRE EPA CERTIFICATION TO PURCHASE HOWEVER ALL OUR REFRIGERANT KITS ARE FOR PROFESSIONAL USE ONLY BY QULIFIED HVAC TECHNICIANS ONLY.
****FOR USE BY QUALIFIED Refrigeration and Air Conditioning TECHNICIANS.
USE ONLY IN AIR CONDITIONING SYSTEMS DESIGNED FOR R404A.
DO NOT MIX WITH ANY OTHER REFRIGERANT.
Refrigerant Can Notes
**WARNING**
*ALWAYS WEAR EYE PROTECTION WHEN WORKING WITH REFRIGERANTS.
*ALWAYS WEAR GLOVES WHEN WORKING WITH REFRIGERANTS.
*CONTENT UNDER PRESSURE.
*VAPOR HARMFUL SKIN AND EYE IRRITANT.
DO NOT CONNECT THIS CAN TO THE HIGH PRESSURE SIDE OF THE SYSTEM, THIS MAY CAUSE THE CAN OR CONTAINER TO
BURST AND RESULT IN SERIOUS INJURY.
ALWAYS REPAIR LEAKS BEFORE ADDING REFRIGERANT.
USE ONLY IN SYSTEMS DESIGNED FOR REFRIGERANT R404a.
DO NOT MIX WITH ANY OTHER REFRIGERANT.
FOR LOW PRESSURE SIDE OF THE SYSTEM ONLY!!!!
DO NOT EXPOSE THIS CAN TO HEAT OR STORE IN TEMPERATURES ABOVE 120 F.
HIGH TEMPERATURES MAY CAUSE THE CAN TO BURST.
DO NOT PUNCTURE OR INCINERATE THIS CAN.
DO NOT STORE IN PARKED VEHICLES WHERE THE INSIDE TEMPERATURE MAY EXCEED 120 F.
Do not refill can.
KEEP OUT OF REACH OF CHILDREN.
HFC refrigerants such as R-404A and R-410A,are not currently covered under the EPA Refrigerant sales restriction.
epa
Listed with ExportYourStore.com